141040 The OptiFuse 141040 is a 40A, 42VDC Type I auto-reset circuit breaker designed for heavy-duty, waterproof applications. It offers panel mounting and robust construction.
Mfr Part #:

141040

Mfr Name: OptiFuse
OptiFuse
The OptiFuse 141040 is a 40A, 42VDC Type I auto-reset circuit breaker designed for heavy-duty, waterproof applications. It offers panel mounting and robust construction.
Stock on Request

141040 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Approval Agency
Current Rating (Amps)
Illumination
Mounting Type
Number of Poles
Voltage Rating

141040 Description

Short technical summary and product information.

This OptiFuse 141040 is a high amperage, heavy-duty, waterproof circuit breaker with a Type I automatic reset function. It is rated for 40A and a maximum voltage of 42VDC.

 

The circuit breaker features a panel mount design and a 1/4”-28 stud terminal configuration. The body is constructed from thermoset plastic (UL94V-0) with nickel-plated terminals, ensuring durability in demanding environments. It meets SAE J553, IEC 60934, and SAE J1171 standards, and offers an IP67 ingress protection rating.

 

Electrical specifications include an interrupting rating of 3000A @ 30VDC. The operating temperature range is from -32°C to 82°C (-25°F to 180°F). This breaker is designed for reliable protection in marine and other harsh conditions.

141040 Quick Information

Product Type: Circuit Breaker
Series: Waterproof
Canonical Name: OptiFuse 141040 High Amperage Heavy Duty Waterproof Circuit Breaker
Subcategory: High Amperage

141040 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

141040 Features

  • 40A current rating for high power circuits.
  • 42VDC voltage rating for DC applications.
  • Type I automatic reset functionality.
  • IP67 waterproof and dustproof rating.
  • Panel mount design for easy installation.

141040 Applications

  • Ideal for marine electrical systems.
  • Suitable for heavy-duty DC circuits.
  • Used in harsh environmental conditions.
  • Provides reliable circuit protection.

141040 FAQs

7 frequently asked questions generated from this part’s specifications.
What is the operating voltage of the OptiFuse 141040?

42VDC.

What is the mounting type?

Panel mount.

What is the operating temperature range?

-32°C to 82°C (-25°F to 180°F).

What is the reset type?

Automatic reset.

What is the interrupting rating?

3000A at 30VDC (per ABYC E-11).

What is the ingress protection rating?

IP67.

What approvals does this circuit breaker have?

SAEJ1171, SAEJ1625, UL, SAE J553, IEC 60934.