Ready to onboard?
Are you ready to join DistyParts and
grow your business?
| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Height | |
| High Voltage Output Range (Minimum/Maximum @ Adjustable Regulated, Positive or Negative) | |
| High Voltage Output Range (Minimum/Maximum @ Negative Polarity Models) | |
| High Voltage Output Range (Minimum/Maximum @ Positive Polarity Models) | |
| Iin (Input Current, Nominal) A @ 100% HVout, 100% LOAD (@ 100% HVout, 0% LOAD) | |
| Iin (Input Current, Nominal) A @ 100% HVout, 100% LOAD (@ 100% HVout, 100% LOAD) | |
| Iin (Input Current, Nominal) A @ 100% HVout, 100% LOAD (@ disable/standby state) | |
| Input Voltage | |
| Input Voltage Range | |
| Lead Spacing | |
| Length | |
| Line Regulation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Current | |
| Power (Watts) | |
| Power - Output (Max) | |
| Power Output (Nominal @ Nominal) | |
| Power-On Rise Time < 150 msec @ 100% LOAD (@ 0% LOAD) | |
| Power-On Rise Time < 150 msec @ 100% LOAD (@ 100% LOAD) | |
| Ripple Vpp (@ Standard configuration @ 100% HVout, 100% Load (10 to 100% HVout range) | |
| Ripple Vpp (@ With -F-M option @ 100% HVout, 100% Load (10 to 100% HVout range) | |
| Ripple Vpp (@ With -F-M-C option @ 100% HVout, 100% Load (10 to 100% HVout range) | |
| Stability 0.01% (100 ppm) @ 100% HVout (Nominal @ 100% HVout (after 30 min warmup interval) | |
| Stability 0.01% (100 ppm) @ 100% HVout (Nominal @ per 8 h interval, 100% HVout) | |
| Standard Number | |
| Static Load Regulation | |
| Tape & Reel | |
| Temperature Coefficient 50 ppm/°C (Nominal @ Standard Configuration over operating temperature...) | |
| Temperature Coefficient 50 ppm/°C (Nominal @ With -25 PPM Option over operating temperature range) | |
| Type | |
| Voltage | |
| Width |
The Advanced Energy UltraVolt 10A Series 10A24-P30-I5-M-E is a regulated DC-to-DC converter designed to provide general-purpose high-voltage power. It features a single output with adjustable regulated voltage from 0 to 10,000 VDC and a maximum output power of 30W. The converter accepts nominal input voltages of 12VDC or 24VDC, with specific input voltage ranges provided for each polarity.
Key electrical specifications include output current capabilities up to 3.0 mA, and ripple performance as low as < 0.8 Vpp with specific options. Stability is maintained at 0.01% after warmup, with line and load regulation also at 0.01%. Temperature coefficients are available down to 25 ppm/°C. The unit operates within a case temperature range of -40°C to 65°C.
Designed for ease of installation, this converter features a chassis mount option and a robust, modular design. It is suitable for various applications requiring high-potential DC bias, such as high-potential testing, PMT/APD detectors, optical spectrometers, electrostatics, electrophoresis, electrospray, and mass spectrometers. The converter is UL/cUL recognized and CE marked for LVD and RoHS compliance, adhering to IEC-60950-1 standards.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The maximum output voltage is 10,000 VDC.
The maximum output power is 30W.
The nominal input voltages are 12 VDC and 24 VDC.
The operating temperature range is -40°C to 65°C case temperature.
It is designed for chassis mounting.