Ready to onboard?
Are you ready to join DistyParts and
grow your business?
| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Control Interface | |
| Current | |
| HVout (Output Voltage) VDC (@ Negative Polarity Models) | |
| HVout (Output Voltage) VDC (@ Positive Polarity Models) | |
| Height | |
| Iin (Input Current, Nominal) A @ 100% HVout, 100% LOAD (Nominal @ 100% HVout, 0% LOAD) | |
| Iin (Input Current, Nominal) A @ 100% HVout, 100% LOAD (Nominal @ 100% HVout, 100% LOAD) | |
| Iin (Input Current, Nominal) A @ 100% HVout, 100% LOAD (Nominal @ disable/standby state) | |
| Input Voltage | |
| Input Voltage Range | |
| Lead Spacing | |
| Length | |
| Line Regulation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Current | |
| Output Power | |
| Power (Watts) | |
| Power-On Rise Time < 150 msec @ 100% LOAD (@ 0% LOAD) | |
| Power-On Rise Time < 150 msec @ 100% LOAD (@ 100% LOAD) | |
| Ripple 2, 3 Vpp (@ Standard Configuration) | |
| Ripple 2, 3 Vpp (@ With -F-M Option) | |
| Ripple 2, 3 Vpp (@ With -F-M-C Option) | |
| Stability 0.01% (100 ppm) @ 100% HVout (Typical @ 100% HVout (after 30 min warmup interval) | |
| Stability 0.01% (100 ppm) @ 100% HVout (Typical @ per 8 h interval) | |
| Standard Number | |
| Static Load Regulation | |
| Storage Temperature | |
| Tape & Reel | |
| Temperature Coefficient 50 ppm/°C (Typical @ Standard configuration over operating temperature...) | |
| Temperature Coefficient 50 ppm/°C (Typical @ With -25 PPM option over operating temperature range) | |
| Type | |
| Voltage | |
| Width |
The Advanced Energy UltraVolt 10A series provides regulated high voltage DC-to-DC conversion for general-purpose applications. This specific model, the 10A24-P30-I5-25PPM-F-M-C, delivers a maximum output voltage of 10 kV DC and a maximum output power of 30W. It is designed for a nominal 24 VDC input, with an input voltage range of 23 to 30 VDC.
Key electrical specifications include a maximum output current of 3mA and output ripple as low as 3 Vpp with the -F-M-C option. The converter offers high stability and regulation, with typical line and static load regulation at 0.01%. It features an analog control interface and is available with temperature coefficients down to 25 ppm/°C.
Designed for ease of installation, this unit features a chassis mount option. The operating temperature range is -40°C to 65°C case temperature. Compliance includes CE and cURus recognition, adhering to standard IEC-60950-1.
Typical applications include DC bias supplies for general use, high-potential testing, PMT/APD detectors, optical spectrometers, electrostatics, electrophoresis, electrospray, and mass spectrometers.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The maximum output voltage is 10,000 VDC.
The maximum output power is 30W.
The nominal input voltage is 24 VDC.
It uses an analog control interface.
The operating temperature range is -40°C to 65°C case temperature.
It features a chassis mount.