Ready to onboard?
Are you ready to join DistyParts and
grow your business?
| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| HVout (Output Voltage) VDC (@ Negative Polarity Models) | |
| HVout (Output Voltage) VDC (@ Positive Polarity Models) | |
| Height | |
| Iin (Input Current, Nominal) A @ 100% HVout, 100% LOAD (Nominal @ 100% HVout, 0% LOAD) | |
| Iin (Input Current, Nominal) A @ 100% HVout, 100% LOAD (Nominal @ 100% HVout, 100% LOAD) | |
| Iin (Input Current, Nominal) A @ 100% HVout, 100% LOAD (Nominal @ disable/standby state) | |
| Input Voltage | |
| Input Voltage Range | |
| Length | |
| Line Regulation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Current | |
| Output Power | |
| Power (Watts) | |
| Power-On Rise Time < 150 msec @ 100% LOAD (@ 0% LOAD) | |
| Power-On Rise Time < 150 msec @ 100% LOAD (@ 100% LOAD) | |
| Ripple Vpp (@ Standard configuration) | |
| Ripple Vpp (@ With -F-M option) | |
| Ripple Vpp (@ With -F-M-C option) | |
| Stability 0.01% (100 ppm) @ 100% HVout (Nominal @ 100% HVout (after 30 min warmup interval) | |
| Stability 0.01% (100 ppm) @ 100% HVout (Nominal @ per 8 h interval) | |
| Standard Number | |
| Static Load Regulation | |
| Temperature Coefficient 50 ppm/°C (Nominal @ Standard Configuration over operating temperature...) | |
| Temperature Coefficient 50 ppm/°C (Nominal @ With -25 PPM Option over operating temperature range) | |
| Type | |
| Voltage | |
| Width |
The Advanced Energy UltraVolt 10A series provides regulated DC-to-DC conversion for high voltage applications. This specific model, the 10A12-P4-I5-25PPM-F-M-C, delivers a maximum output voltage of 10,000 VDC with a 4W maximum output power. It is designed for a nominal 12VDC input voltage.
Key electrical specifications include an output current of 0.40mA, with various ripple performance options available. The unit features a temperature coefficient of 25 ppm/°C and operates within a case temperature range of -40 to 65°C. Stability and regulation are maintained at 0.01% under specified conditions.
Designed for ease of integration, this converter features a chassis mount type and an analog control interface. It is recognized by UL/cUL and carries the CE mark, complying with LVD and RoHS directives, and IEC-60950-1 standards.
Typical applications include DC bias supplies, high-potential testing, PMT/APD detectors, optical spectrometers, electrostatics, electrophoresis, electrospray, and mass spectrometers.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The maximum output voltage for positive polarity models is 10,000 VDC.
The maximum output power is 4W.
The nominal input voltage is 12 VDC.
The operating temperature range is -40 to 65°C case temperature.
This unit is designed for chassis mount installation.