Ready to onboard?
Are you ready to join DistyParts and
grow your business?
| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| HVout (@ Negative Polarity Models) | |
| HVout (@ Positive Polarity Models) | |
| Height | |
| Iin (Input Current, Nominal) A (@ 100% HVout, 0% LOAD) | |
| Iin (Input Current, Nominal) A (@ Disable/Standby State) | |
| Iin (Input Current, Nominal) A @ 100% HVout, 100% LOAD | |
| Input Voltage | |
| Input Voltage Range | |
| Length | |
| Line Regulation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Current | |
| Power (Watts) | |
| Power-On Rise Time (@ 0% LOAD) | |
| Power-On Rise Time (@ 100% LOAD) | |
| Ripple Vpp (@ Standard configuration) | |
| Ripple Vpp (@ With -F-M option) | |
| Ripple Vpp (@ With -F-M-C option) | |
| Stability (Typical @ 100% HVout (after 30 min warmup interval) | |
| Stability (Typical @ per 8 h interval) | |
| Standard Number | |
| Static Load Regulation | |
| Temperature Coefficient | |
| Temperature Coefficient (Typical @ Standard Configuration) | |
| Type | |
| Voltage | |
| Width |
The Advanced Energy UltraVolt 10A series provides regulated DC-to-DC conversion for high voltage power applications. This specific model, the 10A12-N4-I5-25PPM-M-E, delivers a maximum output power of 4W and an adjustable regulated output voltage ranging from 0 to 10,000 VDC. It operates with a nominal 12 VDC input voltage and has a maximum output current of 0.40 mA.
Designed for ease of integration, this converter features a chassis mount type and an analog control interface. It offers a temperature coefficient of 25 ppm/°C and operates within an ambient temperature range of -40°C to 65°C. The unit is recognized by UL/cUL and carries a CE mark, complying with LVD and RoHS directives, and IEC-60950-1 standards.
Typical applications include DC to high voltage DC bias supplies, high-potential testing, PMT/APD detectors, optical spectrometers, electrostatics, electrophoresis, electrospray, and mass spectrometers.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The maximum output voltage is 10,000 VDC for positive polarity models and -10,000 VDC for negative polarity models.
The maximum output power is 4W.
The nominal input voltage is 12 VDC.
The operating temperature range is -40°C to 65°C case temperature.
This converter uses a chassis mount type.
The approval agencies are CE and cURus.