106-M2-P30-4.2A The E-T-A 106-M2-P30-4.2A is a single-pole thermal circuit breaker designed for overcurrent protection. It features a 4.2A current rating and a panel mount design.
Mfr Part #:

106-M2-P30-4.2A

Mfr Name: ETA
ETA
The E-T-A 106-M2-P30-4.2A is a single-pole thermal circuit breaker designed for overcurrent protection. It features a 4.2A current rating and a panel mount design.
Stock on Request

106-M2-P30-4.2A Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Ambient Temperature
Breaker Type
Current Rating
Current Rating (Amps)
Insulation Resistance
Mounting Type
Number of Poles
Voltage Rating

106-M2-P30-4.2A Description

Short technical summary and product information.

The E-T-A 106-M2-P30-4.2A is a miniaturized, single-pole thermal circuit breaker that provides reliable overcurrent protection. It meets the requirements of EN 60934 (IEC 60934) standards.

 

This circuit breaker has a rated voltage of 240 VAC and 48 VDC, with a specific current rating of 4.2A. It is designed for panel mounting and features a push-to-reset actuator.

 

Key technical specifications include an interrupting capacity of 6x IN for both AC and DC, and a rupture capacity of 2000A (AC 250V) and 200A (DC 48V) per UL 1077.

 

Typical applications for this thermal circuit breaker include hand tools, domestic appliances, overcurrent protection of PCB conductor paths, marine vehicles, and mobile homes. It operates within an ambient temperature range of -20°C to 60°C.

106-M2-P30-4.2A Quick Information

Product Type: Thermal Circuit Breaker
Series: 106
Canonical Name: E-T-A 106-M2-P30-4.2A Single Pole Thermal Circuit Breaker
Subcategory: Thermal Circuit Breaker

106-M2-P30-4.2A Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

106-M2-P30-4.2A Features

  • Single-pole thermal circuit breaker.
  • Rated for 4.2A current.
  • Supports 240VAC and 48VDC.
  • Panel mount design with push-to-reset.
  • Meets EN 60934 standards.

106-M2-P30-4.2A Applications

  • Suitable for hand tools.
  • Used in domestic appliances.
  • Protects PCB conductor paths.
  • Applicable for marine vehicles.
  • Ideal for mobile homes.

106-M2-P30-4.2A FAQs

7 frequently asked questions generated from this part’s specifications.
What is the rated voltage of the E-T-A 106-M2-P30-4.2A circuit breaker?

The circuit breaker is rated for 240 VAC and 48 VDC.

What is the current rating of the 106-M2-P30-4.2A?

The nominal current rating is 4.2 A, with a current rating range of 0.05 A to 10 A.

What type of circuit breaker is the 106-M2-P30-4.2A?

It is a thermal circuit breaker with a push-to-reset actuator.

What is the operating temperature range for this circuit breaker?

The operating temperature range is -20 °C to 60 °C.

What is the degree of protection for the 106-M2-P30-4.2A?

The operating area has IP40 protection, and the terminal area has IP00 protection.

What is the interrupting capacity of this circuit breaker?

The interrupting capacity is 6 times the rated current for both AC and DC circuits.

What mounting type does the 106-M2-P30-4.2A use?

It uses panel mount with a threadneck mounting type.