| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
215 pcs
|
215 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name |
The LAPP ÖLFLEX® CHAIN 809 CY is a versatile, screened control cable featuring PVC core insulation and a PVC outer sheath. It is designed for applications in power chains, moving machine parts, and EMC-sensitive environments. This cable is suitable for measuring, control, and regulating circuits, as well as general wiring of machines, tools, devices, and control cabinets.
Key features include its high flexibility, oil resistance, and torsion resistance, making it suitable for demanding applications like wind turbine generators. The cable boasts multi-standard certification, including UL AWM Style 20886 and cUL AWM II A/B FT1, which simplifies part variety and reduces costs for export-oriented manufacturers. The tinned-copper braiding ensures EMC compliance, protecting against electromagnetic interference.
Technical specifications include a nominal voltage rating of 300/500 V (VDE) and 1000 V (UL & CSA). The operating temperature range for flexing is 0°C to +70°C (or +80°C for UL/CSA), and for fixed installation, it is -40°C to +70°C (or +80°C for UL/CSA). The minimum bending radius is 10 times the outer diameter for flexing and 4 times for fixed installation. Flammability ratings include UL/CSA VW-1, FT1 and IEC/EN 60332-1-2.
The cable's construction consists of fine-wire, bare copper strands, PVC core insulation, twisted cores, a non-woven wrapping, tinned-copper braiding, and a grey PVC outer sheath.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The nominal voltage rating is 300/500 V according to VDE standards and 1000 V according to UL & CSA standards.
The operating temperature range is 0°C to +70°C for flexing applications and -40°C to +70°C for fixed installations. UL/CSA ratings extend the maximum to +80°C.
It meets UL/CSA flammability standards VW-1 and FT1, and IEC/EN standard 60332-1-2.
The minimum bending radius for flexing applications is 10 times the outer diameter.
Cores are identified with black and white numbers according to VDE 0293-334.