| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
3,000 pcs
|
3000 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request | |
|
1,491 pcs
|
1491 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request | |
|
1,491 pcs
|
1491 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request | |
|
545 pcs
|
545 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| AEC Qualified | |
| AEC-Q | |
| Automotive Grade | |
| Current | |
| Current - Max (Imax) | |
| Halogen Free | |
| Hold Current (IH) | |
| Lead Style | |
| Length | |
| Mounting Type | |
| Operating Temperature | |
| Package / Case | |
| Power Dissipation (PD) | |
| Ratings | |
| Resistance | |
| Resistance - Initial (Rmin) | |
| Resistance - Post Trip (R1max) | |
| Tape & Reel | |
| Thickness (Max) | |
| Time to Trip | |
| Trip Current (IT) | |
| Type | |
| Voltage | |
| Voltage - Max | |
| Width |
The Bel Fuse 0ZCG0110BF2B is a polymeric PTC resettable fuse designed for overcurrent protection. It features a hold current of 1.1A and a trip current of 2.2A, with a maximum voltage rating of 24V DC. The device can handle fault currents up to 100A and dissipates 1.0W of power. Its fast trip time of 0.5 seconds at 8A ensures rapid response to overcurrent events.
This fuse is housed in a compact 1812 (4532 Metric) concave surface mount package, measuring 4.55mm x 3.24mm x 0.90mm. It operates over a wide temperature range of -40°C to 85°C, making it suitable for demanding environments. The low initial resistance of 60mΩ minimizes power loss, while the post-trip resistance of 200mΩ ensures reliable reset behavior.
The 0ZCG0110BF2B is AEC-Q200 qualified, meeting automotive industry reliability standards. It is RoHS compliant, lead-free, and halogen-free, supporting environmental requirements. Typical applications include automotive electronics, USB port protection, battery charging circuits, and industrial power distribution.
The hold current is 1.1 A.
The trip current is 2.2 A.
The maximum voltage is 24 V DC.
The maximum fault current is 100 A.
The time to trip is 0.5 seconds at 8 A.
It is available in a 1812 (4532 Metric) concave surface mount package.
Yes, it is AEC-Q200 compliant.