Ready to onboard?
Are you ready to join DistyParts and
grow your business?
| Category | |
| Manufacturer Name | |
| 2 Conductors Cross Section (Solid) | |
| 2 Conductors Cross Section (Stranded) | |
| 2 Conductors Cross Section (Stranded, TWIN ferrules with plastic sleeve) | |
| 2 Conductors Cross Section (Stranded, ferrules without plastic sleeve) | |
| Actuator Type | |
| Ambient Temperature (Operation) | |
| Breaker Type | |
| Color | |
| Conductor Cross Section (AWG/kcmil) | |
| Conductor Cross Section (Solid) | |
| Conductor Cross Section (Stranded) | |
| Conductor Cross Section Stranded with Ferrule with Plastic Sleeve | |
| Conductor Cross Section Stranded with Ferrule without Plastic Sleeve | |
| Connection Method | |
| Current Rating | |
| Current Rating (Amps) | |
| Depth | |
| ETIM | |
| Fuse Type | |
| Height | |
| Height (NS 35/15) | |
| Height (NS 35/7.5) | |
| Inflammability Class | |
| Insulating Material | |
| Insulating Material Group | |
| Mounting Type | |
| Number of Connections | |
| Number of Levels | |
| Number of Poles | |
| Number of Positions | |
| Packing Unit | |
| Pollution Degree | |
| Screw Thread | |
| Storage Temperature | |
| Stripping Length | |
| Surge Voltage Category | |
| Tape & Reel | |
| Tightening Torque | |
| Width | |
| eCl@ss | |
| height (@ NS 32) |
This Phoenix Contact 0914724 is a thermomagnetic circuit breaker designed for circuit protection. It operates as a single-pole device with a current rating of 100mA and features a convenient lever actuator.
The circuit breaker is designed for mounting on a 35 mm DIN rail, making it suitable for standard industrial control panels and enclosures. It has a width of 12.5 mm and a depth of 96 mm.
Key electrical specifications include a surge voltage category of III and an insulating material group of I. The device supports a wide range of conductor cross-sections, from 0.2 mm² to 6 mm² for solid conductors and 0.2 mm² to 4 mm² for stranded conductors. Connection is made via screw terminals, with a recommended tightening torque between 0.6 Nm and 0.8 Nm.
Environmental conditions for operation range from -30 °C to 60 °C. The circuit breaker also meets flammability class V0 according to UL 94 standards and has a pollution degree of 3.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The current rating is 100mA.
It is designed for mounting on a 35 mm DIN rail.
The ambient temperature range for operation is -30 °C to 60 °C.
It supports solid conductors from 0.2 mm² to 6 mm² and stranded conductors from 0.2 mm² to 4 mm².
It is a thermal magnetic circuit breaker.