0712194 Thermal circuit breaker from Phoenix Contact, rated for 1A current at 250V AC or 65V DC. Suitable for overcurrent protection.
Mfr Part #:

0712194

Mfr Name: Phoenix Contact
Phoenix Contact
Thermal circuit breaker from Phoenix Contact, rated for 1A current at 250V AC or 65V DC. Suitable for overcurrent protection.
Stock on Request

0712194 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Ambient Temperature
Breaker Type
Current Rating (Amps)
Mounting Type
Number of Poles
Voltage Rating

0712194 Description

Short technical summary and product information.

This thermal circuit breaker from Phoenix Contact, part number 0712194, is rated for 1A nominal current and can operate at 250V AC or 65V DC. The device has an interrupting capacity of 6 times the nominal current for currents from 0.25A to 4A, and 8 times for 6A to 10A. It also meets UL 1077 with 2000A interrupting capacity at 250V AC and 200A at 65V DC. The operating temperature range is -20°C to +60°C. It has a rated surge voltage of 2.5kV and contamination class 2. The service life is 3000 cycles at 1xIN inductive load and 500 cycles at 2xIN inductive load. This thermal circuit breaker is suitable for overcurrent protection in various industrial and commercial applications.

0712194 Quick Information

Product Type: Thermal Circuit Breaker
Canonical Name: Thermal Circuit Breaker, 1A, 250V AC/65V DC, Phoenix Contact 0712194
Subcategory: Thermal Circuit Breakers

0712194 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: Compliant

0712194 Features

  • Rated for 1A at 250V AC or 65V DC.
  • Interrupting capacity up to 2000A AC per UL 1077.
  • Operating temperature range from -20°C to +60°C.
  • Rated surge voltage of 2.5kV.
  • Service life of 3000 cycles at rated current.

0712194 Applications

  • Overcurrent protection in industrial control panels.
  • Protection for DC power supplies up to 65V.
  • Suitable for equipment requiring UL 1077 compliance.
  • Use in applications with inductive load switching.

0712194 FAQs

7 frequently asked questions generated from this part’s specifications.
What is the nominal voltage rating of this circuit breaker?

The nominal voltage is 250V AC and 65V DC.

What is the operating temperature range?

-20°C to +60°C.

What is the interrupting capacity according to UL 1077?

2000A at 250V AC and 200A at 65V DC.

What is the service life under inductive load?

3000 cycles at 1xIN, 500 cycles at 2xIN.

What is the rated surge voltage?

2.5kV.

What is the contamination class?

2.

What is the interrupting capacity per IEC?

6 times the nominal current for currents 0.25A to 4A, and 8 times for 6A to 10A.