| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
202 pcs
|
202 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Admissible Ambient Temperature | |
| Approval Agency | |
| Breaking Capacity | |
| Breaking Capacity @ Rated Voltage | |
| Breaking Capacity Range | |
| Climatic Category | |
| Current Rating | |
| Current Rating (Amps) | |
| Endcap Material | |
| Fuse Type | |
| Melting I²t | |
| Mounting Type | |
| Operating Temperature | |
| Operating Temperature Range | |
| Package / Case | |
| Rated Current Range | |
| Rated Voltage AC | |
| Response Time | |
| Size | |
| Size / Case | |
| Storage Temperature Range | |
| Tape & Reel | |
| Tube Material | |
| Unit Weight | |
| Voltage Rating |
The Schurter 0034.3111 is a 5x20mm cartridge glass fuse from the FST series. It is rated for 250mA at 250VAC and features a time-lag T (slow blow) characteristic, designed to withstand temporary inrush currents without nuisance opening. The fuse has a breaking capacity of 35A at rated voltage and a melting I²t value of 0.238 A²s.
This fuse is constructed with a glass tube and nickel-plated copper alloy endcaps. It requires a holder for mounting and operates over an ambient temperature range of -55°C to 125°C. The climatic category is 55/125/21 per IEC 60068-1. Storage conditions are 0°C to 60°C with maximum 70% relative humidity. The unit weight is approximately 1 gram.
Applications include primary protection in equipment where slow-blow characteristics are needed to handle transient surge currents. The fuse carries approvals from CCC, cURus, and VDE, indicating compliance with relevant safety standards.
The current rating is 250 mA.
The voltage rating is 250 VAC.
The breaking capacity is 35 A at rated voltage (250 VAC).
It is a time-lag T (slow blow) fuse.
The fuse is in a 5mm x 20mm cartridge package.
The fuse is approved by CCC, cURus, and VDE.
The admissible ambient temperature range is -55 °C to 125 °C.