What are Uncategorized ?
Top Subcategories
Popular subcategories in Uncategorized on DistyParts.
Parts in this category
Tap rows to select parts
Compare stocked parts across manufacturers and distributors, then add lines to your RFQ.
| Part & Mfr | Total Stock | Pricing & RFQ | |
|---|---|---|---|
PCE Instruments
The RS232 TTL interface converter is a device-independent solution for converting an RS232 signal into a TTL signal. The RS232 TTL interface converter can also be used to convert a TTL signal into an RS 232 signal. If, for example, the RS232 TTL interface converter is to be used to evaluate the data output of a scale, which communicates via RS232, with the help of a microprocessor, the RS232 TTL interface converter can now be interposed between the transmitter and receiver.
When converting the signals, the RS232 TTL interface converter enables a transmission speed of up to 115,200 baud. The baud rate itself does not have to be set for the RS232 TTL interface converter. This is set by the RS232 TTL interface converter itself. In addition to converting a parallel signal, the signal can be switched to a crossed signal via the RS232 TTL interface converter by setting the switch. Thus the RS232 TTL interface converter can be used universally and quickly.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
With this portable Bluetooth profilometer - roughness tester, you can quickly and precisely measure the roughness of a wide variety of surfaces. To do this, the roughness meter with Bluetooth is placed on the surface to be tested. With the positioning device, the roughness meter can be aligned on a wide variety of surfaces. A measurement with the Bluetooth roughness meter can be carried out at the touch of a button. After the measurement has been carried out, the measured value is shown to the operator on the display of the Bluetooth roughness meter. A progress diagram of the surface is also shown on the display.
When measuring the surface roughness, there are various measurement parameters that provide information about the roughness of the surface, for example the maximum roughness depth, the mean roughness depth and many other measurement parameters. After a measurement has been carried out, these can be displayed in the data memory of the Bluetooth roughness meter.
After each measurement of the roughness, the recorded measured values ​​are saved in the roughness meter with Bluetooth. Up to 20 measurement sequences can be saved with the Bluetooth roughness meter. In order to process or analyze these further, the Bluetooth roughness meter can be connected to a PC via the micro-USB interface and read out, analyzed and further processed using the free software in the download portal.
This roughness meter has a Bluetooth interface. This Bluetooth interface can be used to establish a direct connection with an Android device. This has several advantages. The stored data can be displayed and analyzed directly on the Android device. The measured values ​​measured by the Bluetooth roughness meter can also be exported and forwarded by the mobile device. In addition to transferring the measured values, it is also possible to control the Bluetooth roughness meter via the connected mobile device. This means that the measurement parameters can be set directly on the roughness meter with Bluetooth. At the same time, a measurement process can be started with the Bluetooth roughness meter via the Bluetooth interface. This has the particular advantage that, in contrast to starting via the buttons on a roughness meter, no vibrations are transmitted to the Bluetooth roughness meter. As a result, the operator receives a more precise and at the same time more reliable measurement result from the Bluetooth roughness meter.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
This analog, rotating viscosity measuring device provides the operator with a quick, on-site viscosity reading for production control. This viscosity measuring device is robust, easy to use, and also suitable for mobile use. An analog pointer indicates the viscosity value. The electronic drive ensures smooth rotation and thus repeatable measured values.
This analog viscosity measuring device is designed as a control tool in production (e.g., at various production stages) or for incoming inspection of raw materials, auxiliary materials, and additives, and for checking the viscosity of varnishes, paints, pastes, and other materials during further processing. As an analog viscosity measuring device, it is the optimal alternative to expensive digital devices for detecting trends or conducting comparative measurements. - Ideal for on-site inspections -.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The Two-Stage digital manifold gauge from PCE Instruments is equipped with a powerful motor that provides high torque. The motor power is 1.5 HP (1.1 kW), ensuring reliable and efficient performance. With an impressive flow rate of 340 l/min, the digital manifold gauge is capable of efficiently evacuating large volumes of refrigerants. The vacuum pump is equipped with 1/4" and 3/8" connections, allowing for versatility and adaptability to various refrigerant hoses and applications, such as heat pumps.
Our Two-Stage digital manifold gauge is equipped with a state-of-the-art filter element that effectively contributes to reducing oil mist. This filter element not only enhances the pump's lifespan but also ensures a cleaner working environment and contributes to environmental preservation. The ergonomically designed rubber handle allows for secure transportation and ease of handling. The digital manifold gauge is used to evacuate heat pumps, air conditioning units, and refrigeration systems before filling them with refrigerant. This is essential for removing moisture and air from the system, thereby improving the efficiency of the air conditioning system.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The Density Meter is a modern measuring instrument that enables precise analyses of wet and dry density, degree of compaction and moisture content in soil. A Density Meter is used in various areas, including road construction, foundation construction, landfill construction, environmental and hydraulic engineering. They help engineers and site managers to analyse soil properties and quality to ensure that soils are suitable for the intended construction projects. By precisely recording the density, degree of compaction and moisture content, well-founded decisions can be made on further soil treatment, compaction or stabilisation. It makes a decisive contribution to quality assurance and enables a well-founded assessment of material properties in order to carry out construction projects efficiently, safely and sustainably.
Equipped with an integrated GPS, it provides precise location data for every measurement. The large 5-inch touch screen ensures user-friendly operation and quick navigation through the functions. Thanks to the fast measuring time of just 5 seconds, the Density Meter enables efficient work and prompt results. The Density Meter has an internal data memory with capacity for up to 4200 measured values, allowing extensive data to be saved directly and analysed later. The included software assists in analysing the collected data.
In addition, the Density Meter measures the soil temperature and provides precise density values in real time. A practical status bar shows the GPS status, the memory capacity, the available battery voltage, a possible low battery level as well as the date and time. All relevant information is therefore always visible at a glance so that you can fully concentrate on the measurements with the Density Meter.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The configurable universal measuring transducer for electrical signals is a signal doubler and signal converter for process signals. A 4 ... 20-mA and 0 ... 10V DC signal can be applied to the input. The configurable universal transmitter for electrical signals supplies excitation voltage if required. It has 2 outputs, whereby output 1 can be set to 4 ... 20-mA and output 2 to 4 ... 20-mA or 0 ... 10V DC. It also has quadruple isolation between power supply, input signal, output 1 and output 2.
Circuit isolation prevents ground loops and propagation of voltage spikes, protecting equipment and signal integrity. Configuration system (numbers and keypad) are accessible behind the front cover and offer easy and quick configuration. The signal duplicator has a "password" function to block access to the configuration. The configurable universal transmitter for electrical signals is designed for industrial use, with the possibility of integration into a variety of applications, reduced costs, excellent quality and optional customization of the device for individual use.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The transmitter has an adjustable measuring range of 0… 600 V AC/DC and can therefore measure a wide variety of voltages. For example, it is possible to connect the transmitter to the supply line in order to monitor the applied voltage. In addition to voltage measurement, the transmitter can also measure the current directly with a maximum adjustable measuring range of 0 … 5 A AC/DC. A current transformer can be connected to the transmitter to expand the current range. The measured value is then converted by the transmitter into a standardized analog 4 … 20 mA or 0 … 10 V signal. Thus the transmitter is the ideal extension of a process control.
Since the input and output range can be set identically, the transmitter can be used for galvanic decoupling. The transmitter is configured directly via the keypad. This means that no additional cable or software is required for the settings of the signal converter. The transmitter is mounted on a DIN rail. The transmitter is operated with a voltage of 18 … 265 V AC/DC at a frequency of 45 … 65 Hz.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The current measuring transducer and millivolt signals offer a wide range of configuration options for converting signals. The output signal can be selected between 4 ... 20 mA and 0 ... 10 VDC can be selected. Configurable for measuring load cells in the range 0 ... 5 mV to 0 ... 80 mV, also with bipolar ranges from ±5 mV to ±80 mV. It also provides an excitation voltage of +5 VDC to supply the load cell. The current measuring transducer has a universal power supply from 18 to 265 VAC/DC and isolation between input, output and current circuits.
The input and output signal ranges are customizable via a keypad with front display. The current measuring transducer has a "password" function to block unauthorized access to the configuration menu. It also has an "SOS" mode to assist with critical maintenance and repair work without interfering with the manufacturing process. Designed for industrial use, with potential integration into a wide range of applications.
Configurable information messages (tare value, mV at terminals, input signal value, output signal value, configured label, signal percentage, process value, excitation voltage value and excitation current value). Manual "force" functions for generating low and high output signals to validate the remote instrumentation during installation.
For more details on the voltage transformer, please refer to the operating instructions under Documents / Downloads.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
Current Measuring Transducer for process signals, temperatures, resistors and potentiometers. Offers a wide range of configuration options for converting signals. The output signal can be selected between 4 ... 20 mA and 0 ... 10 VDC can be selected for the output signal.
Configurable for measuring 4 ... 20 mA and 0 ... 10 VDC process signals, both active and passive. If required, the universal measuring transducer provides an excitation voltage to supply the transducer with current. Type J,K,N,E,T,R,S,C,B thermocouples can also be connected. Furthermore, thermoresistors Pt100 (2 and 3 wires), Pt500 and Pt1000, several NTC sensors, resistors and potentiometer signals.
The universal measuring transducer has a universal power supply from 18 to 265 VAC/DC and 3-way insulation between input, output and current circuits.
The input and output signal ranges are customisable via a keypad with front display. The Current Measuring Transducer has a "password" function to block unauthorised access to the configuration menu. It also has an "SOS" mode to assist with critical maintenance and repair work without interfering with the manufacturing process. Designed for industrial use, with potential integration into a wide range of applications.
For further details, please refer to the operating instructions under Documents / Downloads.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The transmitter converts an analog input signal into a corresponding analog output signal. The input and output signals from the transmitter are completely galvanically isolated. The input and output range is set via two buttons. The type of adjustment is displayed on an internal LED display.
Over 100 different combinations of input and output, as well as the free scaling within the set ranges, make this transmitter a universally applicable device and save an expensive and laborious storage of different types. Since the input and output ranges can also be set identically, the transmitter can also be used for galvanic decoupling. The transmitter is simply snapped onto a C or DIN rail. The signal converter can be operated with a voltage between 18 ... 265V AC / DC.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The decibel meter consists of a measuring microphone with handle and a wall holder with 1.5 m cable, a noise transmitter and a digital display. The main application of the noise meter is the continuous noise measurement and noise monitoring of factory halls, production rooms and large events (discotheques, folk festivals, kart tracks, etc.). The digital display has a relay output for the control of alarm horns or blinkers for visual or acoustic warning and a control output.
The limit value for this alarm output can be programmed on the display. The analogue output signal can also be used for controlling window flaps ... or the signals of the transmitter can be stored, evaluated and documented on a logger. The noise warning device is very easy to connect and can be operated via 240 V mains power. The cabling is the only installation task that the customer has to carry out himself. Thus, this noise warning device can be used quickly for monitoring purposes.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The digital thermometer allows for quick temperature checks. It is also lightweight and ergonomically designed to make taking measurements as comfortable as possible.
The temperature sensor of the probe thermometer is made of stainless steel and is ideal for food use. An LED is located parallel to the sensor, allowing measurements to be taken with the digital thermometer even in dark conditions.
When the probe is extended, the device turns on automatically. The measuring electronics of the probe thermometer are well protected in an ABS housing, and the protection class of the probe thermometer is IP54.
The display of the probe thermometer rotates depending on the orientation of the device, allowing the readings to be read comfortably. If the thermometer is not in use, the device turns off after 90 seconds.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
This is a portable battery-powered industrial pallet scale or floor scale featuring two heavy-duty parallel weighing beams made of lacquered steel that can be positioned up to 4 m / 13 ft apart. Thus, the adjustable width accommodates multiple pallet, box and container sizes. In addition, the scale's stainless-steel-encased display can be placed up to 5 m / 16 ft away from the weighing beams, allowing for wall mounting.
- Portable
- Multiple TARE for whole weighing range
- Threshold, sum-up and counting functions
- Ingress protection rating: IP 54
- Ideal for use in warehouse, storage facility, shipping, receiving, loading dock, logistical, supply chain, retail, inventory and stock room applications
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
This is a portable battery-powered industrial pallet scale or floor scale featuring two heavy-duty parallel weighing beams made of lacquered steel that can be positioned up to 4 m / 13 ft apart. Thus, the adjustable width accommodates multiple pallet, box and container sizes. In addition, the scale's stainless-steel-encased display can be placed up to 4 m / 13 ft away from the weighing beams, allowing for wall mounting.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
This is a portable battery-powered industrial pallet scale or floor scale featuring two heavy-duty parallel weighing beams made of lacquered steel that can be positioned up to 4 m / 13 ft apart. Thus, the adjustable width accommodates multiple pallet, box and container sizes. In addition, the scale's stainless-steel-encased display can be placed up to 4 m / 13 ft away from the weighing beams, allowing for wall mounting.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
Our tachometer is a digital, battery-operated optical measuring device that, thanks to its optical sensor, can be used up to a distance of 50 cm from the measuring point. It covers a measuring range of 2.5 to 99,999 revolutions per minute (rpm) and offers a resolution of 0.1 rpm to deliver reliable results.
Equipped with minimum, maximum, last, and average value functions, the tachometer allows you to record current and extreme readings over the measured period. The 1.8-inch LCD display provides a clear readout under all conditions. The compact design, measuring 127 x 55 x 30 mm, makes the device portable and easy to use. The laser enables precise measurements at a distance of 50 to 500 mm. To take a measurement, the trigger button must be held down. The values ​​are updated every second on our tachometer.
Our tachometer automatically shuts off after 60 seconds of inactivity to prevent accidental discharge of the 2 AAA batteries. Ideal for use in various industries such as mechanical engineering, automotive, and maintenance, it offers the precision and reliability for a wide range of applications.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
Our tachometer, with a measuring range of 0.5 to 19999 rpm and a resolution of 0.1 rpm, enables accurate and reliable measurements in a wide range of applications. With a measuring rate of 0.8 seconds, the tachometer delivers fast results. It offers several measurement functions to choose from, including MAX, MIN, LAST, and AVG, to capture various aspects of speed measurement. The units can be flexibly selected between rpm, m/min, and ft/min.
The tachometer features a low battery indicator and is powered by two AAA batteries. An automatic shut-off after 60 seconds contributes to energy savings. The tachometer is compact and can be operated with just three buttons. The 1.8-inch LCD display ensures clear and easy-to-read measured values.
In addition to the tachometer, the scope of delivery includes an adapter and four additional rubber pads for various measurements. These accessories expand the device's application possibilities and make it a practical tool for users in various industries.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The tachometer features contact-based speed measurement. The measuring range of the contact-based speed measurement on the tachometer is 0.5 to 99,999 RPM. Two rubberized measuring tips, one with an inner and one with an outer cone, are included in the scope of delivery to transmit the speed to the tachometer. When using contact-based measurement on the tachometer, the speed can also be determined in m/min, for example, using the measuring wheel.
In addition to contact measurement, the tachometer can also measure the speed optically. For this purpose, a 1 x 1 cm piece of reflective tape is affixed to the test object. The tachometer can determine the speed through reflection. Additionally, the speed of the tachometer can be determined using the strobe function. With this function, the tachometer emits multiple flashes in succession. To quickly adjust the flash frequency of the tachometer, the flash frequency can be doubled or halved. The speed is determined using the strobe function of the tachometer as soon as the test object can be seen continuously and stationary through the flash.In addition to measuring speed and rotational speed, the tachometer can also measure temperature. Any type-K thermocouple can be connected for this purpose. A PT1000 resistance temperature sensor can also be connected if required.
Thanks to its numerous functions, the tachometer can be used in a wide range of applications. For example, the tachometer is used to determine the speed of conveyor belts and the rotational speed of ventilation systems. The tachometer can optionally be equipped with an ISO calibration certificate.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The thermometer has two measuring inputs. Each measuring input from the thermometer can be connected to a thermocouple of type K, T and J. With a measuring rate of 2 Hz, the thermometer shows rapid temperature fluctuations. With the high accuracy and a resolution of 0.01 °C, these rapid temperature fluctuations can also be displayed precisely by the thermometer.
With a data memory of 20,000 measuring points, the thermometer can be used for a long period of time. A data point on the thermometer contains a measured value per channel and date as well as the current time. When the thermometer is connected to a computer, it is recognized as a removable disk. This allows the thermometer to be connected to computers with different operating systems, as no additional software is required for further analysis. The measurement data from the thermometer can be saved as TXT, CSV, XLS and DLG format.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The thermometer offers precise temperature monitoring. With a measuring range of -210 to 1370 °C and support for thermocouple types K and J, it enables accurate measurements in different environments. Its 4 input channels allow simultaneous monitoring of multiple measuring points, making it ideal for complex applications.
Before the recording mode can be started, the thermometer must be connected to a PC via a micro USB port and the parameters configured using the PC software. The storage interval, the number of measured values and also the starting point of the data logger can be set. Up to 32000 data records can be recorded with this function. The interval can be set in steps from 1s to max. 24h. The thermometer software can also be used to export the data in pdf and csv format.
The MIN, MAX, AVG and HOLD measurement functions enable precise data recording and analysis. The thermometer switches off automatically after 20 minutes of inactivity to save energy and extend the operating time of the 3.7 V Li-Ion battery. The "Auto Power Off" function can also be deactivated. The thermometer is charged via the micro-USB interface and comes in a practical case for transportation.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The 4-channel thermometer for thermocouples allows for the display and archiving of multiple temperature sensors simultaneously. It can be connected to up to 8 different types of thermocouples. Notably, the data logger offers high accuracy, especially with Type K thermocouples, with an accuracy of Type K ± (0.04% of reading + 0.3 K).
The measurement overview of the 4-channel thermometer provides a quick overview of the 4 displayed temperatures. Another view displays the maximum, minimum, and average values since the start of measurement. Additionally, each channel can be compared with all other channels, showing the current measurement value of the channel and the difference from the reference channel. The 4-channel thermometer can store up to 100 data sets, each with a maximum of 100,000 readings. Adjustable alarm thresholds for upper and lower temperature values can highlight measurements in red. Using the included PC software, data stored by the 4-channel thermometer can be imported, graphically represented, analyzed, and archived.
The 4-channel thermometer for thermocouples is well-suited for areas where temperature monitoring is critical. Possible applications include furnace inspections, temperature-sensitive component development processes, or laboratory experiments. For the temperature data logger, we offer a wide range of thermocouple probes, which can be found in the accessories section.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The simple design and an absolutely straightforward operation make it possible for the practitioner to use the adhesion tester as an instrument for daily adhesion tests. Using adhesive with rapid curing, the tests can be performed by the user in the shortest possible time.
The pull-off type adhesion tester is designed for measure the adhesion value of paints and other coatings on the base and between layers or cohesive materials. The tensile adhesion tester is manufactured according to EN13144 and ISO 4624.
The testing with the mechanical tensile adhesion tester is performed in the following way. On the testing cover a dolly is glued and, after the glue is dried, it is pulled-off with the spring-system of the device. The force which is applied for pulling-off the glued dolly is displayed as a numerical value on the scale of the device. This value is the value of adhesion.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
Our Thermometer offers reliable temperature measurement within a range from -20 °C to 550 °C (-4 °F to 1022 °F). The infrared images are displayed with a resolution of 384 x 288 pixels on the 3.5-inch colour display. The compact and user-friendly design of the Thermometer features an ergonomic handle and an intuitive key control system directly below the screen for easy operation.
The camera offers multiple colour palettes, including rainbow and iron oxide red, as well as various viewing options to accurately capture thermal data. With a thermal sensitivity of 0.06 °C and an adjustable emissivity of 0.01 to 1.0, even subtle temperature differences can be detected. It saves more than 40000 images in the internal 6 GB memory in JPG format. With a frame rate of 25 Hz, a wavelength range of 8 ... 14 μm and selectable automatic power-off times, this Thermometer is a versatile tool for professional and private users.
The unique feature of this Thermometer is the possibility of a remote connection via a WiFi network, e.g. to a smartphone from which the Thermometer can be set remotely or the recorded thermal images can be saved directly to the end device. Once a smartphone is connected to the Thermometer via WiFi, the corresponding colour palette, emissivity or even the display of the maximum and minimum value can be set remotely. Thanks to the Thermometer, not only heat losses but also leaks in water and heating systems or non-functioning mechanical components of various systems (motors, bearings, belts, heat pumps, etc.) can be easily detected.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
This thermal imaging camera for preventive maintenance is the ideal tool for preventive maintenance and repair. This thermal imaging camera is a must-have for electricians, metalworkers, or general maintenance personnel, especially when working in harsh environmental conditions. It is used for troubleshooting and preventing faults in electrical systems, electromechanical equipment, machinery in production processes, and heating, ventilation, and air conditioning systems. Operators can use the high-resolution PCE-TC 30N thermal imaging camera for preventive maintenance to detect developing faults in machines and equipment. This makes preventive maintenance and repair easy. The heart of the high-resolution PCE-TC 30N thermal imaging camera is an uncooled microbolometer with a measurement resolution of 160 x 120 pixels.
The PCE-TC 30N thermometer is ergonomically designed for one-handed operation. Its very low weight of 389 g makes it ideal for analyzing machines and systems. In operational maintenance and repair, this thermal imaging camera is used, for example, for the optical monitoring of bearings and bearing housings, heat exchangers, steam separators, etc., or for checking electrical systems. With a sensitivity of less than 0.1 °C, the PCE-TC 30N thermal imaging camera offers a maximum measurement accuracy of ±2 °C or ±2% in a temperature range of -20 to +300 °C. The color display on this thermal imaging camera has the option of automatically finding and displaying the warmest and coldest measuring points in the measurement image. The built-in LED enables easier location of fault sources in the dark. With its powerful functions, irregularities on machines are immediately detected, and appropriate preventative measures can be taken on the spot. The saved thermal images can be transferred to a PC or laptop using the included connection cable.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The temperature meter has a measuring range of -20 ... +550 °C. This means that the temperature meter already covers a wide temperature range of measuring tasks. With a frame rate of 25 Hz, problems can be quickly localised with the temperature meter. The picture-in-picture function allows the real image to be displayed simultaneously with the thermal image. The app enables a clear display and operation of the temperature meter.
When connecting the temperature meter to a PC, there are two different functions that can be selected in advance in the settings. With the "PC Connection" setting, the temperature meter is recognised as a mass data storage device. This allows all image, video and measurement data to be copied directly from the temperature meter. With the "PC Camera" function, the temperature meter is recognised as a webcam by the PC. This has the advantage that the current image from the temperature meter can be displayed on a PC, for example, during online meetings or training sessions. In both cases, the temperature meter is independent of the operating system.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
Siemens
|
Send RFQ
|
Price on request
Price and Stock
on Request Send RFQ
|
|
PCE Instruments
The infrared thermometer is the ideal tool for repair work and prevention measures. This thermal imager is a must-have for electricians, fire fighters, locksmiths, or general service personnel for trouble shooting and fault prevention on electrical equipment, electromechanical equipment, production process machinery, heating, ventilation, and air conditioning systems, especially when working in harsh environments.
In preventative maintenance, the high-resolution thermal imager is ideal for maintaining or repairing machinery or other equipment. At the heart of the high-resolution thermography camera is an uncooled microbolometer (uncooled focal plane array) with a resolution of 220 x 160 pixels. The thermography camera was designed in ergonomic design for one-hand operation. Due to the very low weight of just 424 g, it is ideal for analyzing machinery and equipment, for building thermography and many other applications. The thermographic camera offers a measurement accuracy of ± 2°C / 3.6°F or ± 2% in a temperature range of -20°C ... 300°C / -4 ... 572°F, with a sensitivity of less than 0.
On the color display of this thermal imager there is the possibility to automatically find and display the warmest and coldest measuring point in the measurement image. With the powerful features, irregularities are immediately detected and appropriate action can be taken on the spot. The stored thermal image recordings can be transmitted to a PC or laptop using the corresponding connection cable. The internal 3 GB memory of the thermographic camera can accommodate more than 20,000 thermal images.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
Our Thermometer offers reliable temperature measurement within a range from -20 °C to 550 °C (-4 °F to 1022 °F). The infrared images are displayed with a resolution of 384 x 288 pixels on the 3.5-inch colour display. The compact and user-friendly design of the Thermometer features an ergonomic handle and an intuitive key control system directly below the screen for easy operation.
The camera offers multiple colour palettes, including rainbow and iron oxide red, as well as various viewing options to accurately capture thermal data. With a thermal sensitivity of 0.06 °C and an adjustable emissivity of 0.01 to 1.0, even subtle temperature differences can be detected. It saves more than 40000 images in the internal 6 GB memory in JPG format. With a frame rate of 25 Hz, a wavelength range of 8 ... 14 μm and selectable automatic power-off times, this Thermometer is a versatile tool for professional and private users.
The unique feature of this Thermometer is the possibility of a remote connection via a WiFi network, e.g. to a smartphone from which the Thermometer can be set remotely or the recorded thermal images can be saved directly to the end device. Once a smartphone is connected to the Thermometer via WiFi, the corresponding colour palette, emissivity or even the display of the maximum and minimum value can be set remotely. Thanks to the Thermometer, not only heat losses but also leaks in water and heating systems or non-functioning mechanical components of various systems (motors, bearings, belts, heat pumps, etc.) can be easily detected.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval from 1 second to 12 hours can be set for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000 mm. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the ultrasonic flow meter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with ferrous metal. The sensors have a dimension of 91 x 52 x 44 mm.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval from 1 second to 12 hours can be set for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 M SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. The sensors of the ultrasonic flow meter can be attached to ferrous pipes with the built-in magnets. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per unit of heat simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 M SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. The sensors of the ultrasonic flow meter can be attached to ferrous pipes with the built-in magnets. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the ultrasonic flow meter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with ferrous metal. The sensors have a dimension of 91 x 52 x 44 mm.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per unit of heat simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 MR SENSOR
Separate on-rail sensors for pipe sizes DN 50 ... 700 / 57 ... 720 mm. The temperature resistance is between -30 ... 160 °C. The sensor on the respective rail is located on a rail and can therefore be positioned appropriately. Magnets are located underneath the rails which make it possible to hold on to pipes with a ferrous metal by themselves.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the Portable Ultrasonic Flow Meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the Portable Ultrasonic Flow Meter. The installation aid graphically displays the signal quality of the Portable Ultrasonic Flow Meter. In addition, it is graphically displayed whether the sensors of the Portable Ultrasonic Flow Meter are positioned at the correct distance from each other. To carry out flow measurements with the Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The Portable Ultrasonic Flow Meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the Portable Ultrasonic Flow Meter. Start and stop conditions and the storage interval from 1 second to 12 hours can be set for the Portable Ultrasonic Flow Meter. A memory point of the Portable Ultrasonic Flow Meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the Portable Ultrasonic Flow Meter. 10 million measuring points can be stored on the Portable Ultrasonic Flow Meter.
With the optional software, the recorded measured values can be read out from the Portable Ultrasonic Flow Meter. For analysis, the measured values from the Portable Ultrasonic Flow Meter can be displayed in tabular and graphic form. For further processing of the measured values from the Portable Ultrasonic Flow Meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the Portable Ultrasonic Flow Meter can be set via the software. A live view of the measured values from the Portable Ultrasonic Flow Meter is also possible with the software.
In order to determine the amount of heat with the Portable Ultrasonic Flow Meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the Portable Ultrasonic Flow Meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the Portable Ultrasonic Flow Meter can determine the amount of heat. If required, the Portable Ultrasonic Flow Meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the Portable Ultrasonic Flow Meter is used, for example, in the inspection of heating systems.
The LC colour display of the Portable Ultrasonic Flow Meter has a size of 2.8" and is therefore easy to read. Optionally, the Portable Ultrasonic Flow Meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 M SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. The sensors of the Portable Ultrasonic Flow Meter can be attached to ferrous pipes with the built-in magnets. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval from 1 second to 12 hours can be set for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have a particularly small dimension of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors for the ultrasonic flow meter can be connected to the pipe by means of detachable cable ties.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have a particularly small dimension of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors for the ultrasonic flowmeter can be connected to the pipe by means of detachable cable ties.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the ultrasonic flow meter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with ferrous metal. The sensors have a dimension of 91 x 52 x 44 mm.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the Ultrasonic Flow Meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the Ultrasonic Flow Meter. The installation aid graphically displays the signal quality of the Ultrasonic Flow Meter. In addition, it is graphically displayed whether the sensors of the Ultrasonic Flow Meter are positioned at the correct distance from each other. To carry out flow measurements with the Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The Ultrasonic Flow Meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the Ultrasonic Flow Meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the Ultrasonic Flow Meter. A memory point of the Ultrasonic Flow Meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the Ultrasonic Flow Meter. 10 million measuring points can be stored on the Ultrasonic Flow Meter.
With the optional software, the recorded measured values can be read out from the Ultrasonic Flow Meter. For analysis, the measured values from the Ultrasonic Flow Meter can be displayed in tabular and graphic form. For further processing of the measured values from the Ultrasonic Flow Meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the Ultrasonic Flow Meter can be set via the software. A live view of the measured values from the Ultrasonic Flow Meter is also possible with the software.
In order to determine the amount of heat with the Ultrasonic Flow Meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the Ultrasonic Flow Meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the Ultrasonic Flow Meter can determine the amount of heat. If required, the Ultrasonic Flow Meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the Ultrasonic Flow Meter is used, for example, in the inspection of heating systems.
The LC colour display of the Ultrasonic Flow Meter has a size of 2.8" and is therefore easy to read. Optionally, the Ultrasonic Flow Meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have a particularly small dimension of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors for the ultrasonic flowmeter can be connected to the pipe by means of detachable cable ties.
PCE-TDS 200 M SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. With the built-in magnets on the sensors for the Ultrasonic Flow Meter, they can be attached to ferrous pipes. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have a particularly small dimension of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors for the ultrasonic flowmeter can be connected to the pipe by means of detachable cable ties.
PCE-TDS 200 M SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. With the built-in magnets on the sensors for the ultrasonic flow meter, they can be attached to ferrous pipes. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the Clamp-on Ultrasonic Flow Meter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with ferrous metal. The sensors have a dimension of 91 x 52 x 44 mm.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have a particularly small dimension of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors for the ultrasonic flowmeter can be connected to the pipe by means of detachable cable ties.
PCE-TDS 200 M SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. With the built-in magnets on the sensors for the ultrasonic flow meter, they can be attached to ferrous pipes. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
This Ultrasonic testing device with special sensors for various applications. In general, the wall thicknesses of all homogeneous materials can be measured with the thickness meter. For damping or scattering materials such as plastic or cast a special sensor is available. An angled 90° sensor also enables measurements at hard-to-reach measuring points. The speed of sound can be set freely on the thickness meter and thus adapted to a wide variety of materials.
The measured values ​​are displayed directly on the easy-to-read TFT color display. Due to the internal memory, which can be read out via the optionally available software, different measuring points can be clearly stored. The non-destructive ultrasound measuring method enables the measurement even on end products. Thanks to the Echo-Echo working mode, even coated workpieces can be measured (only with PCE-TG 300-P5EE sensor).
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 SR SENSOR
Connected on rail sensors for pipe sizes DN 15 ... 100 / 20 ... 108 mm. Both sensors are located on one rail to simplify the positioning of the sensors. For easier handling there is a handle on the rail. Magnets are located underneath the rails to enable them to hold on to pipes with ferrous metal by themselves.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the Portable Ultrasonic Flow Meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the Portable Ultrasonic Flow Meter. The installation aid graphically displays the signal quality of the Portable Ultrasonic Flow Meter. In addition, it is graphically displayed whether the sensors of the Portable Ultrasonic Flow Meter are positioned at the correct distance from each other. To carry out flow measurements with the Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The Portable Ultrasonic Flow Meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the Portable Ultrasonic Flow Meter. Start and stop conditions and the storage interval from 1 second to 12 hours can be set for the Portable Ultrasonic Flow Meter. A memory point of the Portable Ultrasonic Flow Meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the Portable Ultrasonic Flow Meter. 10 million measuring points can be stored on the Portable Ultrasonic Flow Meter.
With the optional software, the recorded measured values can be read out from the Portable Ultrasonic Flow Meter. For analysis, the measured values from the Portable Ultrasonic Flow Meter can be displayed in tabular and graphic form. For further processing of the measured values from the Portable Ultrasonic Flow Meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the Portable Ultrasonic Flow Meter can be set via the software. A live view of the measured values from the Portable Ultrasonic Flow Meter is also possible with the software.
In order to determine the amount of heat with the Portable Ultrasonic Flow Meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the Portable Ultrasonic Flow Meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the Portable Ultrasonic Flow Meter can determine the amount of heat. If required, the Portable Ultrasonic Flow Meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the Portable Ultrasonic Flow Meter is used, for example, in the inspection of heating systems.
The LC colour display of the Portable Ultrasonic Flow Meter has a size of 2.8" and is therefore easy to read. Optionally, the Portable Ultrasonic Flow Meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have a particularly small dimension of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors for the Portable Ultrasonic Flow Meter can be connected to the pipe by means of detachable cable ties.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval from 1 second to 12 hours can be set for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the ultrasonic flow meter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with ferrous metal. The sensors have a dimension of 91 x 52 x 44 mm.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval from 1 second to 12 hours can be set for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 M SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. The sensors of the ultrasonic flow meter can be attached to ferrous pipes with the built-in magnets. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
Linear Technology
|
Send RFQ
|
Price on request
Price and Stock
on Request Send RFQ
|
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per unit of heat simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 M SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. The sensors of the ultrasonic flow meter can be attached to ferrous pipes with the built-in magnets. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the ultrasonic flow meter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with ferrous metal. The sensors have a dimension of 91 x 52 x 44 mm.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 MR SENSOR
Separate on-rail sensors for pipe sizes DN 50 ... 700 / 57 ... 720 mm. The temperature resistance is between -30 ... 160 °C. The sensor on the respective rail is located on a rail and can therefore be positioned appropriately. Magnets are located underneath the rails, which make it possible to hold on to pipes with a ferrous metal by themselves.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the Portable Ultrasonic Flow Meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the Portable Ultrasonic Flow Meter. The installation aid graphically displays the signal quality of the Portable Ultrasonic Flow Meter. In addition, it is graphically displayed whether the sensors of the Portable Ultrasonic Flow Meter are positioned at the correct distance from each other. To carry out flow measurements with the Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The Portable Ultrasonic Flow Meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the Portable Ultrasonic Flow Meter. Start and stop conditions and the storage interval from 1 second to 12 hours can be set for the Portable Ultrasonic Flow Meter. A memory point of the Portable Ultrasonic Flow Meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the Portable Ultrasonic Flow Meter. 10 million measuring points can be stored on the Portable Ultrasonic Flow Meter.
With the optional software, the recorded measured values can be read out from the Portable Ultrasonic Flow Meter. For analysis, the measured values from the Portable Ultrasonic Flow Meter can be displayed in tabular and graphic form. For further processing of the measured values from the Portable Ultrasonic Flow Meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the Portable Ultrasonic Flow Meter can be set via the software. A live view of the measured values from the Portable Ultrasonic Flow Meter is also possible with the software.
In order to determine the amount of heat with the Portable Ultrasonic Flow Meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the Portable Ultrasonic Flow Meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the Portable Ultrasonic Flow Meter can determine the amount of heat. If required, the Portable Ultrasonic Flow Meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the Portable Ultrasonic Flow Meter is used, for example, in the inspection of heating systems.
The LC colour display of the Portable Ultrasonic Flow Meter has a size of 2.8" and is therefore easy to read. Optionally, the Portable Ultrasonic Flow Meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 M SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. The sensors of the Portable Ultrasonic Flow Meter can be attached to ferrous pipes with the built-in magnets. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per unit of heat simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have a particularly small dimension of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors for the ultrasonic flow meter can be connected to the pipe by means of detachable cable ties.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have a particularly small dimension of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors for the ultrasonic flowmeter can be connected to the pipe by means of detachable cable ties.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the ultrasonic flow meter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with ferrous metal. The sensors have a dimension of 91 x 52 x 44 mm.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
|
PCE Instruments
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have a particularly small dimension of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors for the ultrasonic flowmeter can be connected to the pipe by means of detachable cable ties.
PCE-TDS 200 M SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. With the built-in magnets on the sensors for the ultrasonic flow meter, they can be attached to ferrous pipes. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |