| Part & Mfr | Total Stock | Pricing & RFQ | Actuator Type | Approval Agency | Circuit | Conduit Thread Size | Current Rating (Amps) | Features | Holding Force | Ingress Protection | Must Operate | Must Release | Operating Temperature | Termination Style | Type | Voltage | Voltage Rating | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Omron
|
10
|
Price on request
10
|
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NC | - | 750mA (AC) | Cable Length 3m | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Cable Leads | Non-Locking | - | 240VAC | |
Omron
|
2
|
Price on request
2
|
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NO/NC | M20 | 3A (AC) | - | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 240VAC | |
Schneider Electric
|
2
|
Price on request
2
|
Panel Disconnect | CSA, TUV, UL | DPST-NO/NC | M20 x 1.5 | 750mA (AC), 550mA (DC) | - | - | IP66 - Dust Tight, Waterproof | - | - | -25°C ~ 60°C | Cable Leads | Key Locking | - | 240VAC, 24VDC | |
Omron
|
1
|
Price on request
1
|
Panel Disconnect | CCC, CE, CSA, UL | DPST-NC (DB) + SPST-NC (DB) | 1/2" NPT | 6A (AC) | Status Indicator | 71kgf | IP67 - Dust Tight, Waterproof | - | - | -10°C ~ 55°C | Screw Terminal | Solenoid Release | 24VDC | 115VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus, TUV | DPST-NO/NC | - | 500mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 3mm | 8mm | -10°C ~ 55°C | Cable Leads | Magnetic | - | 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus, TUV | DPST-NO/NC | - | 500mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 3mm | 8mm | -10°C ~ 55°C | Cable Leads | Magnetic | - | 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | - | - | 100mA (DC) | Automatic Reset | - | IP69K - Dust Tight, High Temp Water Jets, Waterproof | 10mm | 25mm | -25°C ~ 70°C | Cable with Connector (M12) | RFID | 24VDC | 24VDC | |
Idec
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, TUV, UL | DPST-NC x 2 | M20 | 2.5A (AC/DC) | - | 143kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 55°C | Spring Terminal | Solenoid Locking | 24VDC | 125VAC, 30VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | 3PST-2NC/1NO | G1/2 | 3A (AC) | - | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 240VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NC x 2 | PG13.5 | 3A (AC), 270mA (DC) | Status Indicator | 133kgf | IP67 - Dust Tight, Waterproof | - | - | -10°C ~ 55°C | Screw Terminal | Solenoid Release | 24VDC | 240VAC, 250VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | - | DPST-NC | - | - | - | - | - | - | - | -25°C ~ 55°C | Screw Terminal | Non-Locking | 24VDC | - | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | DPST-NC | - | 5A (AC), 2A (DC) | - | 612gf | IP67 - Dust Tight, Waterproof | - | - | -20°C ~ 80°C | Cable with Connector (M12) | Non-Locking | - | 100VAC, 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | 3PST-2NC/1NO + DPST-NO/NC | M20 | 3A (AC), 270mA (DC) | Status Indicator | 133kgf | IP67 - Dust Tight, Waterproof | - | - | -10°C ~ 55°C | Screw Terminal | Solenoid Locking | 24VDC | 240VAC, 250VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, CSA, UL | DPST-NO/NC (DB/DM) + SPST-NC (DB) | G1/2 | 3A (AC) | - | 71kgf | IP67 - Dust Tight, Waterproof | - | - | -10°C ~ 55°C | Screw Terminal | Solenoid Release | 24VDC | 250VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus, TUV | SPST-NO | - | 10mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 5mm | 15mm | -10°C ~ 55°C | Cable Leads | Magnetic | 24VDC | 24VDC | |
Idec
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, TUV, UL | DPST-NO/NC x 2 | M20 | 2.5A (AC/DC) | - | 143kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 55°C | Spring Terminal | Solenoid Locking | 24VDC | 125VAC, 30VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | 3PST-2NC/1NO + SPST-NC | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Locking | 24VAC/DC | 24VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus, TUV | DPST-NO/NC | - | 500mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 7mm | 10mm | -10°C ~ 55°C | Cable Leads | Magnetic | - | 24VDC | |
Idec
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, TUV, UL | DPST-NO/NC x 2 | M20 | 2.5A (AC/DC) | - | 143kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 55°C | Spring Terminal | Solenoid Release | 24VDC | 125VAC, 30VDC | |
Honeywell Sensing and Productivity Solutions
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | DPST-NO/NC | - | 3A (AC), 550mA (DC) | - | - | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 85°C | Connector (M12) | Non-Locking | - | 120VAC, 125VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | 3PST-2NC/1NO | - | 200mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 8mm | 20mm | -25°C ~ 80°C | Cable Leads | Magnetic | 24VDC | 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NC x 2 | PG13.5 | 3A (AC), 270mA (DC) | Status Indicator | 133kgf | IP67 - Dust Tight, Waterproof | - | - | -10°C ~ 55°C | Screw Terminal | Solenoid Release | 24VDC | 240VAC, 250VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | - | SPST-NC | - | - | - | - | - | - | - | -25°C ~ 55°C | Screw Terminal | Non-Locking | 24VDC | - | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus, TUV | SPST-NO | - | 10mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 5mm | 15mm | -10°C ~ 65°C | Cable Leads | Magnetic | 24VDC | 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | 3PST-2NC/1NO x 2 | G1/2 x2 | 3A (AC), 270mA (DC) | - | 306kgf | IP67 - Dust Tight, Waterproof | - | - | -10°C ~ 55°C | Screw Terminal | Solenoid Release | 24VDC | 240VAC, 250VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CCC, CE | SPST-NO | - | 100mA (DC) | - | - | IP40 | 15mm | - | -20°C ~ 60°C | Screw Terminal | Magnetic | - | 100VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cURus, TUV | 3PST-2NC/1NO x 2 | 1/2" NPT | 1.5A (AC), 220mA (DC) | Status Indicator | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -10°C ~ 55°C | Connector | Non-Locking | 24VDC | 120VAC, 125VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cURus, TUV | 3PST-2NC/1NO x 2 | 1/2" NPT | 1.5A (AC), 220mA (DC) | Status Indicator | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -10°C ~ 55°C | Connector | Non-Locking | 24VDC | 120VAC, 125VDC | |
Schneider Electric
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CSA, UL | DPST-NO/NC | - | 100mA (DC) | - | - | IP66/IP67 - Dust Tight, Water Resistant, Waterproof | - | - | -25°C ~ 85°C | Connector (M8) | Magnetic | - | 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | DPST-NC + SPST-NO | M16 | 4A (AC/DC) | - | 612gf | IP67 - Dust Tight, Waterproof | - | - | -20°C ~ 80°C | Screw Terminal | Non-Locking | - | 230VAC, 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | 3PST-2NC/1NO | - | 300mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 7 ~ 12mm | 12 ~ 25mm | -10°C ~ 55°C | Cable Leads | Magnetic | - | 30VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | - | - | 100mA (DC) | Automatic Reset | - | IP69K - Dust Tight, High Temp Water Jets, Waterproof | 10mm | 25mm | -25°C ~ 70°C | Cable with Connector (M12) | RFID | 24VDC | 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | 3PST-2NC/1NO + SPST-NC | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Locking | 24VAC/DC | 24VAC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, CSA, UL | DPST-NO | M20 | 10A (AC), 6A (DC) | - | - | IP65 - Dust Tight, Water Resistant | - | - | -30°C ~ 80°C | Screw Terminal | - | - | 100VAC, 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | - | - | 100mA (DC) | Automatic Reset | - | IP69K - Dust Tight, High Temp Water Jets, Waterproof | 10mm | 25mm | -25°C ~ 70°C | Cable with Connector (M12) | RFID | 24VDC | 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NC x 2 | G1/2 | 3A (AC), 270mA (DC) | Status Indicator | 133kgf | IP67 - Dust Tight, Waterproof | - | - | -10°C ~ 55°C | Screw Terminal | Solenoid Locking | 24VDC | 240VAC, 250VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | DPST-NO/NC x 2 | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Locking | 24VAC/DC | 24VAC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | 3PST-NC + SPST-NC | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Locking | 24VAC/DC | 24VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | 3PST-2NC/1NO x 2 | G1/2 x2 | 3A (AC), 270mA (DC) | - | 306kgf | IP67 - Dust Tight, Waterproof | - | - | -10°C ~ 55°C | Screw Terminal | Solenoid Release | 24VDC | 240VAC, 250VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | DPST-NO/NC x 2 | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Release | 110/230VAC | 24VAC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | 3PST-2NC/1NO + SPST-NC | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Locking | 24VAC/DC | 24VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | 3PST-2NC/1NO | M20 | 5A (AC), 2A (DC) | - | 102kgf | IP67 - Dust Tight, Waterproof | - | - | -20°C ~ 60°C | Screw Terminal | Solenoid Release | 24VAC/DC | 100VAC, 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CCC, CE | SPST-NO | - | 100mA (DC) | - | - | IP40 | 15mm | - | -20°C ~ 60°C | Screw Terminal | Magnetic | - | 100VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, CSA, UL | DPST-NO/NC | M16 | 10A (AC), 6A (DC) | - | - | IP65 - Dust Tight, Water Resistant | - | - | -30°C ~ 80°C | Screw Terminal | Non-Locking | - | 110VAC, 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
- | CE | - | - | - | - | - | - | - | - | -40°C ~ 200°C | - | Trapped Key Exchange Unit | - | - | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NO/NC | PG13.5 | 3A (AC) | - | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 240VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Shaft | CCC, CE, cULus, TUV | DPST-NO/NC | G1/2 | 10A (AC), 2.5A (DC) | - | - | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Hinge | - | 120VAC, 125VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, CSA, UL | 3PST-2NC/1NO | M20 | 10A (AC), 6A (DC) | - | - | IP65 - Dust Tight, Water Resistant | - | - | -30°C ~ 80°C | Screw Terminal | Non-Locking | - | 110VAC, 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | 3PST-2NC/1NO | M20 | 3A (AC) | - | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 240VAC | |
Celduc Inc.
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE | 3PST-2NC/1NO | - | 100mA (DC) | - | - | IP66/IP67 - Dust Tight, Water Resistant, Waterproof | 8mm | 20mm | -25°C ~ 85°C | Cable Leads | Magnetic | - | 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Shaft | CE, CSA, UL | DPST-NC | M20 | 10A (AC), 6A (DC) | - | - | IP65 - Dust Tight, Water Resistant | - | - | -30°C ~ 80°C | Screw Terminal | Hinge | - | 110VAC, 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Shaft | CE, CSA, UL | DPST-NO/NC | M20 | 10A (AC), 6A (DC) | - | - | IP65 - Dust Tight, Water Resistant | - | - | -30°C ~ 80°C | Screw Terminal | Hinge | - | 110VAC, 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NO/NC | M20 | 3A (AC) | - | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 240VAC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, CSA, UL | DPST-NO/NC | M20 | 10A (AC), 6A (DC) | - | 2kgf | IP65 - Dust Tight, Water Resistant | - | - | -30°C ~ 80°C | Screw Terminal | Non-Locking | - | 110VAC, 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, CSA, UL | DPST-NO/NC | M20 x3 | 10A (AC), 6A (DC) | - | - | IP65 - Dust Tight, Water Resistant | - | - | -30°C ~ 80°C | Screw Terminal | Non-Locking | - | 110VAC, 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, CSA, UL | DPST-NC | M20 | 10A (AC), 6A (DC) | - | - | IP65 - Dust Tight, Water Resistant | - | - | -30°C ~ 80°C | Screw Terminal | Non-Locking | - | 110VAC, 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | - | SPST-NO | - | - | - | - | - | - | - | -25°C ~ 55°C | Screw Terminal | Non-Locking | 24VDC | - | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, CSA, UL | DPST-NO/NC | M20 | 10A (AC), 6A (DC) | - | - | IP65 - Dust Tight, Water Resistant | - | - | -30°C ~ 80°C | Screw Terminal | Non-Locking | - | 110VAC, 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | 3PST-2NC/1NO | - | 300mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 7 ~ 12mm | 12 ~ 25mm | -10°C ~ 55°C | Cable Leads | Magnetic | - | 30VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | - | - | 100mA (DC) | Manual Reset | - | IP69K - Dust Tight, High Temp Water Jets, Waterproof | 10mm | 25mm | -25°C ~ 70°C | Cable with Connector (M12) | RFID | 24VDC | 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | - | - | 100mA (DC) | Automatic Reset | - | IP69K - Dust Tight, High Temp Water Jets, Waterproof | 10mm | 25mm | -25°C ~ 70°C | Cable with Connector (M12) | RFID | 24VDC | 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus, TUV | 3PST-2NC/1NO | - | 500mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 7mm | 10mm | -10°C ~ 55°C | Cable Leads | Magnetic | - | 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, CSA, UL | DPST-NO/NC | M20 | 10A (AC), 6A (DC) | - | - | IP65 - Dust Tight, Water Resistant | - | - | -30°C ~ 80°C | Screw Terminal | Non-Locking | - | 110VAC, 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | DPST-NO/NC | - | 100mA (AC/DC) | - | - | IP67 - Dust Tight, Waterproof | 9mm | 12mm | -10°C ~ 55°C | Cable Leads | Magnetic | - | 230VAC, 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | - | - | 100mA (DC) | Automatic Reset | - | IP69K - Dust Tight, High Temp Water Jets, Waterproof | 10mm | 25mm | -25°C ~ 70°C | Cable with Connector (M12) | RFID | 24VDC | 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | - | - | 100mA (DC) | Automatic Reset | - | IP69K - Dust Tight, High Temp Water Jets, Waterproof | 10mm | 25mm | -25°C ~ 70°C | Cable with Connector (M12) | RFID | 24VDC | 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | - | - | 100mA (DC) | Manual Reset | - | IP69K - Dust Tight, High Temp Water Jets, Waterproof | 10mm | 25mm | -25°C ~ 70°C | Cable with Connector (M12) | RFID | 24VDC | 24VDC | |
Idec
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, TUV, UL | DPST-NO/NC + DPST-NC | M20 | 2.5A (AC/DC) | - | 143kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 55°C | Spring Terminal | Solenoid Release | 24VDC | 125VAC, 30VDC | |
Idec
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, TUV, UL | DPST-NO/NC + DPST-NC | M20 | 2.5A (AC/DC) | - | 143kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 55°C | Spring Terminal | Solenoid Locking | 24VDC | 125VAC, 30VDC | |
Idec
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, TUV, UL | DPST-NC x 2 | M20 | 2.5A (AC/DC) | - | 143kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 55°C | Spring Terminal | Solenoid Release | 24VDC | 125VAC, 30VDC | |
Idec
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, TUV, UL | 3PST-NC + SPST-NC | M20 | 2.5A (AC/DC) | - | 143kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 55°C | Spring Terminal | Solenoid Release | 24VDC | 125VAC, 30VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus, TUV | SPST-NO | - | 10mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 5mm | 15mm | -10°C ~ 55°C | Cable with Connector (M12) | Magnetic | 24VDC | 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | 3PST-2NC/1NO | - | 200mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 8mm | 20mm | -25°C ~ 80°C | Cable Leads | Magnetic | 24VDC | 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | DPST-NO/NC | - | 100mA (AC/DC) | - | - | IP67 - Dust Tight, Waterproof | 9mm | 12mm | -10°C ~ 55°C | Cable Leads | Magnetic | - | 230VAC, 24VDC | |
Idec
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus, TUV | 3PST-NC x 2 | 1/2" NPT | 10A (AC), 8A (DC) | Status Indicator | 306kgf | IP67 - Dust Tight, Waterproof | - | - | -20°C ~ 55°C | Screw Terminal | Solenoid Release | 24VDC | 125VAC, 30VDC | |
Idec
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, TUV, UL | DPST-NC x 2 | M20 | 2.5A (AC/DC) | - | 143kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 55°C | Spring Terminal | Solenoid Release | 24VDC | 125VAC, 30VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | 3PST-2NC/1NO | - | 200mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 8mm | 20mm | -25°C ~ 80°C | Cable Leads | Magnetic | 24VDC | 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | 3PST-NC + DPST-NC | PG13.5 | 3A (AC), 270mA (DC) | Status Indicator | 133kgf | IP67 - Dust Tight, Waterproof | - | - | -10°C ~ 55°C | Screw Terminal | Solenoid Locking | 24VDC | 240VAC, 250VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | DPST-NO/NC x 2 | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Release | 24VAC/DC | 24VAC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | 3PST-NC + SPST-NC | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Release | 24VAC/DC | 24VAC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | 3PST-2NC/1NO + SPST-NC | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Release | 24VAC/DC | 24VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | 4PST-2NO/2NC (DB/DM) | M20 x3 | 4A (AC/DC) | - | 122kgf | IP67 - Dust Tight, Waterproof | - | - | -20°C ~ 55°C | Screw Terminal | Solenoid Release | 24VAC/DC | 230VAC, 24VDC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | DPST-NO/NC + DPST-NC | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Release | 110/230VAC | 24VAC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | DPST-NO/NC + DPST-NC | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Release | 110/230VAC | 24VAC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | DPST-NO/NC x 2 | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Release | 110/230VAC | 24VAC | |
Banner Engineering Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | 3PST-2NC/1NO + SPST-NC | M20 | 1A (AC) | Manual Override | 153kgf | IP67 - Dust Tight, Waterproof | - | - | -25°C ~ 70°C | Screw Terminal | Solenoid Release | 110/230VAC | 24VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, cULus | 4PST-2NO/2NC (DB/DM) | M20 x3 | 4A (AC/DC) | - | 122kgf | IP67 - Dust Tight, Waterproof | - | - | -20°C ~ 55°C | Screw Terminal | Solenoid Locking | 24VAC/DC | 230VAC, 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus | DPST-NC | - | 200mA (DC) | Status Indicator, Magnetic Latching | 61kgf | IP69K - Dust Tight, High Temp Water Jets, Waterproof | 1mm | 10mm | -25°C ~ 40°C | Cable Leads | RFID | 24VDC | 24VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NO/NC | G1/2 | 3A (AC) | - | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 240VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NC | PG13.5 | 3A (AC) | - | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 240VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NC | G1/2 | 3A (AC) | - | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 240VAC | |
Idec
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NC | G1/2 | 2.5A (AC/DC) | - | 5kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 125VAC, 30VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | 3PST-NC | PG13.5 | 3A (AC) | - | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 240VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | 3PST-2NC/1NO (MBB) | PG13.5 | 3A (AC) | - | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 240VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CCC, CE, cULus, TUV | DPST-NO/NC | M12 | 3A (AC) | - | 6kgf | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Non-Locking | - | 240VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Arm Lever | CCC, CE, cULus, TUV | DPST-NC | G1/2 | 10A (AC), 2.5A (DC) | - | - | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Hinge | - | 120VAC, 125VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Panel Disconnect | CE, CSA, UL | DPST-NC | M20 | 10A (AC) | - | 2kgf | IP67 - Dust Tight, Waterproof | - | - | -40°C ~ 80°C | Screw Terminal | Non-Locking | - | 120VAC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Arm Lever | CCC, CE, cULus, TUV | 3PST-NC | M20 | 10A (AC), 2.5A (DC) | - | - | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Hinge | - | 120VAC, 125VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Arm Lever | CCC, CE, cULus, TUV | 3PST-2NC/1NO | M20 | 10A (AC), 2.5A (DC) | - | - | IP67 - Dust Tight, Waterproof | - | - | -30°C ~ 70°C | Screw Terminal | Hinge | - | 120VAC, 125VDC | |
Omron
|
Send RFQ |
Price on request
Price and Stock
on Request Send RFQ |
Non-Contact | CE, cULus, TUV | SPST-NO | - | 10mA (DC) | - | - | IP67 - Dust Tight, Waterproof | 5mm | 15mm | -10°C ~ 55°C | Cable Leads | Magnetic | 24VDC | 24VDC |