# FCA50F-24 - Cosel AC DC Converter

## Product Summary

The Cosel FCA50F-24 is a 50W AC-DC converter providing a 24V output. It features a chassis mount type and operates with 82% efficiency.

## Product Information

| Field | Value |
| --- | --- |
| Part Number | FCA50F-24 |
| Manufacturer | Cosel |
| Product Type | AC DC Converter |
| Category | Power Supplies - ExternalInternal (Off-Board) |
| Subcategory | Enclosed |
| Mounting Type | Chassis Mount |

## Description

The Cosel FCA50F-24 is an enclosed AC-DC power supply designed for ITE (Commercial) applications. It delivers a stable 24V output with a continuous current of 2.1A and a maximum output wattage of 50W, with a peak capability of 160W.

This power supply operates from a wide AC input voltage range of 187-528V or a DC input range of 265-746V. It boasts a typical efficiency of 82% at 240V AC input. Key electrical specifications include line regulation of 96mV max and load regulation of 150mV max (0-2.1A).

Designed for reliability, the FCA50F-24 includes overcurrent and overvoltage protection. It operates within a temperature range of -10°C to 60°C (with derating) and features convection cooling. The unit is chassis mounted and has dimensions of 150.0mm x 127.0mm x 125.0mm.

## Key Specifications

| Specification | Value |
| --- | --- |
| Applications | ITE (Commercial) |
| Approval Agency | CE, cURus, TUV |
| Current | 2.1 A |
| Efficiency | 78% |
| Features | DC Input Capable |
| Frequency | 47 - 63 Hz |
| Height | 125 mm (4.92") |
| Length | 150 mm (5.91") |
| Mounting Type | Chassis Mount |
| Number of Outputs | 1 |
| Operating Temperature | -10 to +70 °C |
| Power (Watts) | 50 W |
| Storage Temperature | -20 to +75 °C |
| Type | Enclosed |
| Voltage | 24 V |
| Weight | 640g |
| Width | 127 mm (5.00") |

## Availability and Pricing

| Field | Value |
| --- | --- |
| Stock Status | Stock on Request |
| Distributor Count | 0 |
| Total Stock | 0 |
| Pricing Available | No |

## Features

- Provides 24V DC output at 50W continuous power.
- Wide AC input voltage range from 187 to 528V.
- Features 82% typical efficiency at 240V AC.
- Includes overcurrent and overvoltage protection circuits.
- Chassis mount design for easy integration.

## Applications

- Powers commercial information technology equipment racks.
- Supplies control panels in industrial automation systems.
- Drives communication infrastructure and networking hardware.
- Supports medical device power distribution architectures.
- Feeds instrumentation and test measurement equipment.

## Compliance

| Field | Value |
| --- | --- |
| RoHS Status | RoHS3 Compliant |
| REACH Status | REACH Unaffected |
| Moisture Sensitivity Level | 1 Unlimited |

## Documents and Media

- Datasheet: https://static.distyparts.com/disty-files/datasheets/12/45/44/12454445-1776-2140-ND.pdf
- Image: https://static.distyparts.com/disty-files/images/12/45/44/12454445-1776-2140-ND.jpg
- Product Page: https://distyparts.com/product/fca50f-24
- RFQ URL: https://distyparts.com/product/fca50f-24#rfq

## FAQs

### What is the output voltage and current rating?

The FCA50F-24 provides a nominal 24V output at 2.1A, with a peak capacity of 160W and 6.7A.

### Does this converter support DC input?

Yes, the unit accepts DC input voltages ranging from 265V to 746V in addition to its AC input range.

### What are the isolation voltage ratings?

The converter offers 3000VAC isolation between input and output, 2000VAC between input and frame ground, and 500VAC between output and frame ground.

### How does the overcurrent protection function?

Overcurrent protection activates when the load exceeds 105% of the peak current and automatically recovers once the fault condition clears.

### What is the maximum operating temperature?

The unit operates continuously from -10°C to 60°C, with extended operation up to 70°C permitted when applying appropriate power derating.

### What safety and emissions certifications does it hold?

The power supply complies with UL60950-1, C-UL, and EN62368-1 safety standards, and meets FCC Class A, CISPR11 Class A, and EN55011 Class A conducted noise requirements.

### What mounting method and cooling approach are used?

The enclosed chassis mounts securely to a panel or rack and relies on natural convection for thermal management without active fans.

## Related Pages

- Manufacturer: https://distyparts.com/manufacturer/cosel
- Category: https://distyparts.com/category/power-supplies-externalinternal-off-board/ac-dc-converters
- Product Page: https://distyparts.com/product/fca50f-24
- Markdown File: https://distyparts.com/product/fca50f-24.md
- TXT File: https://distyparts.com/product/fca50f-24.txt